Data record tests.leakage-reactance.ieeec57-12-90.reactive-component

Verified 2026-10-24 Confidence: High

Clause 9.4.3 of IEEE C57.12.90-2021 separates impedance voltage into a resistance component, which is corrected to the reference temperature, and a reactance component, which is independent of temperature, and recombines them as a phasor sum.

ProvenanceIEEE C57.12.90-2021 supports data record tests.leakage-reactance.ieeec57-12-90.reactive-component, which is cited on the entry Leakage Reactance.SOURCEIEEE C57.12.90-2021IEEE C57.12.90-2021Licensed standard, clause 9.4.3DATA RECORDtests.leakage-reactance.ieeec57-12-90.reactive-componenttests.leakage-reactance...Verified 2026-10-24ENTRYLeakage ReactanceLeakage ReactanceNo revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceIEEE C57.12.90-2021Licensed standard, clause 9.4.3
Data recordtests.leakage-reactance.ieeec57-12-90.reactive-componentVerified 2026-10-24
EntryLeakage ReactanceNo revisions
Subject
Leakage Reactance (Test methods)
Kind
Method fact
Source
IEEE C57.12.90-2021, clause 9.4.3, Test Code for Liquid-Immersed Distribution, Power and Regulating Transformers, IEEE.

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-24created
2026-10-24review_status unreviewed -> software_reviewed

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record tests.leakage-reactance.ieeec57-12-90.reactive-component." Transformer Testing Reference. 2026-10-24. https://www.transformertestingreference.com/data/tests.leakage-reactance.ieeec57-12-90.reactive-component/.